www.nulec.com.au
Power Division Home | Careers | News | Feedback
  1. Solutions
    • Customised Solutions
    • - Automated Solutions
    • - Loop Automation
    • - ACO
    • - Sectionalisers
    • - WSOS Alert System
    • - WSOS Remote Control
    • - Generator Control
    • - Ready To Go Units
    • - Application Notes
    • - Technical Tips
  2. Products and Services
    • Products Introduction
    • Product Offer
    • - N-Series Recloser
    • - U-Series Recloser
    • - W-Series Recloser
    • - RL-Series Load Break Switch
    • - PTCC Controller
    • - ADVC Controller Range
    • - Configuration Software
    • Accessories
    • Services Introduction
    • - Equipment Support
    • - Training Courses
    • - Product Application Support
  3. Support
    • Contact Us
    • About Schneider
    • Our Brand History
    • About Us
    • Trade Shows
    • Quality Assurance
    • Safety Policy
    • Environmental Policy
    • Frequently Asked Questions
    • Research and Development
    • Manufacturing
  4. Downloads
    • Download WSOS 4
    • Download WSOS 5
    • Videos
  5. Service Log In
    • Log In

Latest News

Popular Links

Newsletter May 2010
Newsletter September 2008
ADVC Controller Range Video Now Available!
ADVC Controller Range Supports DNP over IP
Exhibition for a Smart Future

Global Recloser Solutions

Latest News

RL Series now available in 38kV

02/05/2007

The RL-Series range of pole mounted load-break switches / sectionalisers are available in 15, 27 and now 38kV models. The gas insulated switch is designed to meet the growing requirement for a compact, maintenance free switch offering maximum safety and feeder automation.

Electrical characteristics of the 38kV model are:

Maximum line voltage:

38kV

Fault make capacity (RMS/Peak):

16kA/40kA

Continuous load current (RMS):

630A

Mechanical operations:

3000

Impulse withstand:

170kV



The RL-Series can be used as either a locally or remotely controlled manual switch, or as a fully automated sectionaliser. As a sectionaliser, the switch is connected to the standard controller. This means it can automatically isolate downstream faulty sections of a network in conjunction with an upstream recloser.







Back to the News Page